Goodrive350-19 series VFD Operating
- 141 -
Function
code
Name
Description
Default
value
synchronous motor 1
depended
P02.21
Direct-axis inductance of
synchronous motor 1
0.01
–655.35mH
Model
depended
P02.22
Quadrature-axis inductance
of synchronous motor 1
0.01
–655.35mH
Model
depended
P02.23
Counter-emf constant of
synchronous motor 1
0
–10000
300
P05.01
–
P05.06
Function of multi-function
digital input terminal (S1
–S4,
HDIA,HDIB)
35: Motor 1 switches to motor 2
/
P08.31
Switching between motor 1
and motor 2
0x00
–0x14
Ones: Switch-over channel
0: Switch over by terminal
1: Switch over by MODBUS
communication
2: Switch over by PROFIBUS / CANopen
/Devicenet
3: Switch over by Ethernet
communication
4: Switch over by EtherCat/Profinet
communication
Tens: Motor switch-over during running
0: Disable switch-over during running
1: Enable switch-over during running
00
P12.00
Type of motor 2
0: Asynchronous motor
1: Synchronous motor
0
P12.01
Rated power of
asynchronous motor 2
0.1
–3000.0kW
Model
depended
P12.02
Rated frequency of
0.01Hz
–P00.03 (Max. output frequency) 50.00Hz