Goodrive350-19 series VFD Operating
- 176 -
Setting
Function
Description
signal is output.
35
Reserved
36
Speed/position control
switch-over completed
Output is valid when the mode switch-over is completed
37
–40
Reserved
41
C_Y1
C_Y1 from PLC (You need to set P27.00 to 1.)
42
C_Y2
C_Y2 from PLC (You need to set P27.00 to 1.)
43
C_HDO
C_HDO from PLC (You need to set P27.00 to 1.)
44
C_RO1
C_RO1 from PLC(You need to set P27.00 to 1.)
45
C_RO2
C_RO2 from PLC (You need to set P27.00 to 1.)
46
C_RO3
C_RO3 from PLC (You need to set P27.00 to 1.)
47
C_RO4
C_RO4 from PLC (You need to set P27.00 to 1.)
48
Contactor output
The contactor is VFD controlled. It outputs the ON signal
during running and it outputs the OFF signal during stop.
49
Brake output
It outputs the ON signal during brake release and it
outputs the OFF signal during brake closing.
50
Ready to release the
brake
If the torque verification succeeds, and the running
frequency is no less than the brake release frequency, it
outputs the ON signal when it is ready to release the
brake. Otherwise, it outputs the OFF signal.
51
Ready to close the brake
If the stop command is given, and the running frequency
is no greater than the brake closing frequency, it outputs
the ON signal when it is ready to close the brake.
Otherwise, it outputs the OFF signal.
52
Upward limit position
reached
The output is valid when the upward limit position is
reached.
53
Downward limit position
reached
The output is valid when the downward limit position is
reached.