Goodrive350-19 series VFD Function parameter list
- 327 -
Function
code
Name
Description
Default
value
Modify
Bit10: Z pulse signal source
0: Motor
1: Spindle
Bit11
–15: Reserved
P22.01
Speed of spindle
orientation
During spindle orientation, the speed of the
position point of orientation will be searched, and
then it will switch over to position control
orientation.
Setting range: 0.00
–100.00Hz
10.00Hz
○
P22.02
Deceleration time
of spindle
orientation
Deceleration time of spindle orientation.
Spindle orientation deceleration time means the
time needed for the VFD to decelerate from Max.
output frequency (P00.03) to 0Hz.
Setting range: 0.0
–100.0s
3.0s
○
P22.03
Spindle zeroing
position 0
You can select the zeroing positions of four
spindles by terminals (function code 46, 47).
Setting range: 0
–39999
0
○
P22.04
Spindle zeroing
position 1
Setting range: 0
–39999
0
○
P22.05
Spindle zeroing
position 2
Setting range: 0
–39999
0
○
P22.06
Spindle zeroing
position 3
Setting range: 0
–39999
0
○
P22.07
Spindle
scale-division
angle 1
You can select seven spindle scale-division values
by terminals (function code 48, 49 and 50).
Setting range: 0.00
–359.99
15.00
○
P22.08
Spindle
scale-division
angle 2
Setting range: 0.00
–359.99
30.00
○