Goodrive350-19 series VFD Function parameter list
- 384 -
Function
code
Name
Description
Default
value
Modify
P93.24 can be the value of P93.33 added by
1%
–2%.
P93.27
P93.26
Time t
Output frequency
f
P93.28
Non loose
rope status
Loose
rope
protection
timeout
Target
frequency
Load held
during loose
rope
protection
P93.24
Non loose
rope
status
P93.24
Load held during
loose rope
protection
P93.24+2%
P93.24
Loose rope
protection timeout
P93.24+2%
Output
torque
Output
torque
Output
torque
P93.24, P93.25 setting range: 0.0
–50.0% (rated
torque)
P93.26 setting range: 10.00Hz
–P02.02
P93.27 setting range: 0.0
–50.0s
P93.28 setting range: 0.0
–5.0s
P93.29
Downward loose
rope protection
mode
P93_29 setting range: 0
–1
During downward running, if the loose rope status
occurs after the loose rope detection delay, the
preset processing way is used.
0: Mode 1. The VFD reports the loose rope
protection fault (SLE) and stops.
0
◎
P93.30
REV running time
of downward
loose rope mode
2
5.00s
○
P93.31
Frequency setting
of downward
loose rope mode
5.00Hz
○