Goodrive350-19 series VFD Product overview
- 17 -
Note
:
The input current of 1.5
–500kW VFD models is measured in cases where the input voltage is
380V without an additional reactor.
The rated output current is the output current corresponding to 380V output voltage.
Within the allowable input voltage range, the output current and power cannot exceed the rated
output current and power.
Table 3.4 AC 3PH 520V (-15%)
– 690V (+10%)
VFD model
Output power (kW)
Input current (A)
Output current (A)
GD350-19-022G-6
22
35
27
GD350-19-030G-6
30
40
35
GD350-19-037G-6
37
47
45
GD350-19-045G-6
45
52
52
GD350-19-055G-6
55
65
62
GD350-19-075G-6
75
85
86
GD350-19-090G-6
90
95
98
GD350-19-110G-6
110
118
120
GD350-19-132G-6
132
145
150
GD350-19-160G-6
160
165
175
GD350-19-185G-6
185
190
200
GD350-19-200G-6
200
210
220
GD350-19-220G-6
220
230
240
GD350-19-250G-6
250
255
270
GD350-19-280G-6
280
286
300
GD350-19-315G-6
315
334
350
GD350-19-355G-6
355
360
380
GD350-19-400G-6
400
411
430
GD350-19-450G-6
450
445
465
GD350-19-500G-6
500
518
540
GD350-19-560G-6
560
578
600
GD350-19-630G-6
630
655
680
Note
:
The input current of 22
–350kW VFD models is measured in cases where the input voltage is
660V without DC reactors or input or output reactors.
The input current of 400
–630kW VFD models is measured in cases where the input voltage is
660V with input reactors.
The rated output current is the output current corresponding to 660V output voltage.