Goodrive350-19 series VFD Commissioning
- 73 -
Function
code
Name
Description
Default
(The reverse-running start direction is
always the forward-running
direction.)
Tens place: indicates whether to
enable forward torque for
reverse-running stop
0: Disable
(The reverse-running stop direction
complies with the command.)
1: Enable
(The reverse-running stop direction is
always the forward-running
direction.)
P90.12
Forward brake release current
0.0
–200.0% (of the motor rated
current)
0.0%
P90.13
Reverse brake release current
0.0
–200.0% (of the motor rated
current)
0.0%
P90.14
Forward brake release torque
0.0
–200.0% (of the motor rated
torque)
0.0%
P90.15
Reverse brake release torque
0.0
–200.0% (of the motor rated
torque)
0.0%
P90.16
Forward brake release
frequency
0.00
–20.00Hz
3.00Hz
P90.17
Reverse brake release
frequency
0.00
–20.00Hz
3.00Hz
P90.18
Forward brake closing
frequency
0.00
–20.00Hz
3.00Hz
P90.19
Reverse brake closing
frequency
0.00
–20.00Hz
3.00Hz
P90.20
Delay before forward brake
release
0.000
–5.000s
0.300s
P90.21
Delay before reverse brake
release
0.000
–5.000s
The value 0 indicates the delay
before forward brake release is used.
0.000s
P90.22
Delay after forward brake
release
0.000
–5.000s
0.300s
P90.23
Delay after reverse brake
0.000
–5.000s
0.000s