Goodrive350-19 series VFD Safety precautions
- 4 -
1.4.3 Maintenance and component replacement
Only well-trained and qualified professionals are allowed to perform
maintenance, inspection, and component replacement on the VFD.
Disconnect all the power sources applied to the VFD before terminal wiring, and
wait at least the time designated on the VFD after disconnecting the power
sources.
Take measures to prevent screws, cables and other conductive matters from
falling into the VFD during maintenance and component replacement.
Note:
Use proper torque to tighten the screws. (For details, see "Recommended cable sizes".)
Keep the VFD and its parts and components away from combustible materials during
maintenance and component replacement.
Do not carry out insulation voltage-endurance test on the VFD, or measure the control circuits of
the VFD with megameter.
Take proper anti-static measures on the VFD and its internal parts during maintenance and
component replacement.
1.4.4 Disposal of a scrap VFD
The VFD contains heavy metal. Dispose of a scrap VFD as industrial waste.
When the life cycle ends, the VFD should enter the recycling system. Dispose of
it separately at an appropriate collection point instead of placing it in the normal
waste stream.