Goodrive350-19 series VFD Function parameter list
- 382 -
Function
code
Name
Description
Default
value
Modify
the outermost layer in upward limit)
P93.15 setting range: 100.0
–2000.0mm
(Max. drum diameter in upward limit, including
cable thickness)
P94.05 setting range: 0.00
–655.35m (hook
lowering distance)
P94.06, P94.07 setting range: 0
–65535
P93.16
Enabling
upward/downward
limit position
check
0x00
–0x11
Ones place:
0: The upward limit position is not reached.
1: The upward limit position is reached.
Tens place:
0: The downward limit position is not reached.
1: The downward limit position is reached.
For example, when the upward/downward limit
position needs to be set manually, you can enable
the check of whether the upward/downward limit
position is reached.
P93.17 displays the height from the downward
limit position to the upward limit position, P93.18
displays the height using the downward limit
position as the reference point (the height is 0 at
the downward limit position, the height is positive
when it is above the downward limit position, the
height is negative when it is under the downward
limit position), and P94.05 displays the height
using the upward limit position as the reference
point (the height is 0 at the upward limit position,
and only downward running is allowed when the
upward limit position is reached, and P94.05
indicates the rope droop length when the upward
limit position is not reached).
0x00
○
P93.17
Total height
measured
0.00
–655.35m (Total height measured from the
upward limit position to the downward limit
position)
0.00m
●
P93.18
Measured height
1
-50.00m
–655.35m
(The downward limit position is used as the
0.00m
●