Goodrive350-19 series VFD Function parameter list
- 273 -
Function
code
Name
Description
Default
value
Modify
1: AI1
2: AI2
3: AI3
4: High-speed pulse HDIA
5: Multi-step
6: MODBUS communication
7: PROFIBUS/CANopen/DeviceNet
communication
8: Ethernet communication
9: High-speed pulse HDIB
10: EtherCat/Profinet communication
11: Programmable extension card
12: Reserved
The set target value of process PID is relative
value, the set 100% corresponds to 100% of the
feedback signal of controlled system.
The system operates based on the relative value
(0
–100.0%)
P09.01
Pre-set PID
reference of
keypad
You need to set this parameter when P09.00 is set
to 0, the reference value of this parameter is the
feedback variable of the system.
Setting range: -100.0%
–100.0%
0.0%
○
P09.02
PID feedback
source
This parameter is used to select PID feedback
channel.
0: AI1
1: AI2
2: AI3
3: High-speed pulse HDIA
4: MODBUS communication
5: PROFIBUS/CANopen/DeviceNet
0
○