Goodrive350-19 series VFD Function parameter list
- 332 -
Function
code
Name
Description
Default
value
Modify
current loop
7.2.24 P24 Encoder of motor 2
Function
code
Name
Description
Default
value
Modify
P24.00
Encoder type
display
0: Incremental encoder
1: Resolver-type encoder
2: Sin/Cos encoder
3: Endat absolute encoder
0
●
P24.01
Encoder pulse
number
Number of pulses generated when the encoder
revolves for one circle.
Setting range: 0
–60000
1024
◎
P24.02 Encoder direction
Ones: AB direction
0: Forward
1: Reverse
Tens: Z pulse direction (reserved)
0: Forward
1: Reverse
Hundreds: CD/UVW pole signal direction
0: Forward
1: Reverse
0x000
◎
P24.03
Detection time of
encoder offline
fault
The detection time of encoder offline fault.
Setting range: 0.0
–10.0s
2.0s
○
P24.04
Detection time of
encoder reversal
fault
Detection time of encoder reversal fault.
Setting range: 0.0
–100.0s
0.8s
○