Goodrive350-19 series VFD Operating
- 163 -
Setting
Function
Description
20
Multi-step speed pause
Pause multi-step speed selection function to keep the set
value in present state.
21
Acceleration/deceleration
time selection 1
Use these two terminals to select four groups of
acceleration/decoration time.
Terminal
1
Terminal
2
Acceleration or
deceleration time
selection
Corresponding
parameter
OFF
OFF
Acceleration/
deceleration time 1
P00.11/P00.12
ON
OFF
Acceleration/
deceleration time 2
P08.00/P08.01
OFF
ON
Acceleration/
deceleration time 3
P08.02/P08.03
ON
ON
Acceleration/
deceleration time 4
P08.04/P08.05
22
Acceleration/deceleration
time selection 2
23
Simple PLC stop reset
Restart simple PLC process and clear previous PLC
state information.
24
Simple PLC pause
The program pauses during PLC execution, and keeps
running in current speed step. After this function is
cancelled, simple PLC keeps running.
25
PID control pause
PID is ineffective temporarily, and the VFD maintains
current frequency output.
26
Wobbling frequency pause
(stop at current frequency)
The VFD pauses at current output. After this function is
canceled, it continues wobbling-frequency operation at
current frequency.
27
Wobbling frequency reset
(revert to center frequency)
The set frequency of VFD reverts to center frequency.
28
Counter reset
Zero out the counter state.
29
Switching between speed
The VFD switches from torque control mode to speed