Goodrive350-19 series VFD Installing
- 20 -
Environment
Condition
The max. RH cannot exceed 60% in the environment with corrosive
gases.
Storage
temperature
-30
–+60°C
Running
environment
The installation site must be:
Away from electromagnetic radiation sources.
Away from oil mist, corrosive gases and combustible gases.
Protective from foreign materials such as metal powder, dust, oil, and
water so that the foreign materials will not fall into the VFD. (Do not
install the VFD on inflammables such as wood.)
Away from radioactive substances and combustible objects.
Away from harmful gases and liquids.
With a low salt content density.
No direct sunlight.
Altitude
Lower than 1000m.
When the altitude exceeds 1000m, derate by 1% for every increase of
100m.
When the altitude exceeds 3000m, consult the local INVT dealer or local
INVT office for details.
Vibration
The max. vibration amplitude cannot exceed 5.8m/s
2
(0.6g).
Installation
direction
Install the VFD vertically to ensure good heat dissipation effect.
Note
:
GD350-19 series VFDs need to be installed in a clean and well-ventilated environment based on
the enclosure IP rating.
The cooling air must be clean enough and free from corrosive gases and conductive dust.
4.2.2 Installation direction
The VFD can be installed on the wall or in a cabinet.
The VFD must be installed vertically. Check the installation position according to following
requirements. For details about outline dimensions, see "Dimensional drawings".