Goodrive350-19 series VFD Function parameter list
- 344 -
Function
code
Name
Description
Default
value
Modify
pulse count is automatically reset when there is
signal input.
P28.12
Position
synchronization
proportional
coefficient
0.000
–
10.000
0.005
○
P28.13
Position
synchronization
integral time
0.01
–
80.00
8.00s
○
P28.14
Position
synchronization
filtering time
0.00
–10.00
0.05s
○
P28.15
Enabling the slave
speed deviation
window
0
–1
0: Disable
1: Enable
When the slave adopts the torque control mode,
the speed deviation monitoring function can be
enabled.
0
○
P28.16
Slave positive
speed deviation
window upper
limit
0.00
–50.00Hz
When the actual speed is higher than the given
speed, if the actual speed is higher than (given
speed +P28.16) and exceeds this upper limit, the
speed has to be adjusted.
5.00Hz
○
P28.17
Slave negative
speed deviation
window lower limit
0.00
–50.00Hz
When the actual speed is lower than the given
speed, if the actual speed is lower than (given
speed -P28.17) and exceeds this lower limit, the
speed has be adjusted.
5.00Hz
○
P28.18
Slave rotation
speed regulation
coefficient Kb
0
–50000
Applicable only in master/slave mode 5.
100
○
P28.19
Rotation speed
difference
compensation
coefficient Kc
(Reserved)
0
–50000
Applicable only in master/slave mode 5, in which
there are only one master and one slave.
100
○