Goodrive350-19 series VFD Function parameter list
- 314 -
Function
code
Name
Description
Default
value
Modify
multiple
7.2.20 P20 Encoder of motor 1
Function
code
Name
Description
Default
value
Modify
P20.00
Encoder type
display
0: Incremental encoder
1: Resolver-type encoder
2: Sin/Cos encoder
3: Endat absolute encoder
0
●
P20.01
Encoder pulse
number
Number of pulses generated when the encoder
revolves for one circle.
Setting range: 0
–60000
1024
◎
P20.02 Encoder direction
Ones: AB direction
0: Forward
1: Reverse
Tens: Z pulse direction (reserved)
0: Forward
1: Reverse
Hundreds: CD/UVW pole signal direction
0: Forward
1: Reverse
0x000
◎
P20.03
Detection time of
encoder offline
fault
The detection time of encoder offline fault
(ENC1O).
Setting range: 0.0
–10.0s
1.0s
○
P20.04
Detection time of
encoder reversal
fault
Detection time of encoder reversal fault(ENC1D).
Setting range: 0.0
–100.0s
0.8s
○
P20.05
Filter times of
Setting range: 0x00
–0x99
0x33
○