Goodrive350-19 series VFD Function parameter list
- 361 -
Function
code
Name
Description
Default
value
Modify
Enabling zero
position
detection
Zero
position
detection
S terminal
zero position
input signal
Zero position is valid
VFD
running
status
Stop
Enable
With zero position signal input
FWD/RVS
command
Normal
STC fault
VFD fault
status
Run
P91.07
After the VFD stops, the VFD starts zero position
detection. When the zero position detection delay
is reached, if the detection finds that AI2 is greater
than 1.00V, the analog speed reference deviation
fault AdE is reported.
Enabling zero
position
detection
Zero
position
detection
Analog AI2
S terminal
zero position
input signal
Zero position is valid
P91.07
VFD
running
status
Stop
0
1.00V
AdE fault
Normal
Enable
With zero position signal input
VFD fault
status
Setting range: 0.000
–
10.000s
P91.08
Light load speed
boost function
selection
0
–5
0: Disable
1: Constant power speed boost
2: Constant power speed limit
3: Stepped speed limit
4: Light load speed boost 1
0
◎