Goodrive350-19 series VFD Dimensional drawings
-503-
W1
D1
W2
W2
D2
H2
H1
W4
W3
W2
W2
H4
H2
H3
Figure C.20 660V 160
–220kW VFD flange installation diagram
VFD model
Outline
dimensions
(mm)
Mount
dimensions
(mm)
Hole distance
(mm)
Hole
diameter
(mm)
Screw
Net
weight
(kg)
Gross
weight
(kg)
W1 H1
D1 W2 H2
D2 W3 H3 W4 H4
160kW
–220kW 500 870 358 180 850 178.5 480 796 60 37
11
M10
85
110
C.6.3 Floor installation dimensions
W4
W2
W2
H1
H2
D1
W1
W3
D2
D2
3- ø13.0
6- ø12.0
Figure C.21 660V 250
–355kW VFD floor installation diagram
VFD model
Outline dimensions
(mm)
Mount dimensions
(mm)
Hole
diameter
(mm)
Screw
Net
weight
(kg)
Gross
weight
(kg)
W1
H1 D1 W4 W2 W3 H2
D2
250kW
–355kW 750 1410 380 680 230 714 1390 150
13/12
M12/M10 135
165