Содержание UM Series

Страница 1: ...pair services USA 1 888 932 9183 Canada 1 905 829 2505 Emergency After hours 1 416 624 0386 Servicing USA and Canada Scroll down to view your document Over 100 years cumulative experience 24 hour rush...

Страница 2: ...UM Series DC Servo Control SERVO DRIVE Installation Operating Manual 4 00 MN1213...

Страница 3: ...r Transformer 3 4 Power Wiring 3 5 Signal Wiring 3 6 Optional Input Connections 3 8 Section 4 Adjustments and Start Up 4 1 Overview 4 1 Initial Settings 4 1 Start Up Velocity Mode 4 2 Start Up Torque...

Страница 4: ...ii Table of Contents MN1213...

Страница 5: ...by unauthorized persons misused abused or improperly installed and has been used in accordance with the instructions and or ratings supplied This warranty is in lieu of any other warranty or guarantee...

Страница 6: ...ctly contact the place of purchase for return instructions Safety Notice This equipment contains high voltages Electrical shock can cause serious or fatal injury Only qualified personnel should attemp...

Страница 7: ...of the motor shaft and driven equipment Be certain that unexpected motor shaft movement will not cause injury to personnel or damage to equipment Peak torque of several times the rated motor torque c...

Страница 8: ...connected to a permanent main power source not a portable power source Suitable fusing and circuit protection devices are required Caution The safe integration of the drive into a machine system is t...

Страница 9: ...pplications S Bolt tightening Current mode operation is also useful if a Baldor motion controller is precisely controlling the velocity loop In this configuration tachometer feedback is not required U...

Страница 10: ...Fault Logic Circuitry functions are described in the following paragraphs Excess Current Limit A comparator checks motor current for overload conditions beyond rated output If the comparator is trippe...

Страница 11: ...of the control Several other factors should be carefully evaluated when selecting a location for installation 1 Clearance must be provided for air flow 2 Altitude derating Up to 3300 feet 1000 meters...

Страница 12: ...s of noise may cause detrimental operation For example analog speed and torque inputs are often scaled at 5 to 10VDC maximum with a typical resolution of one part in 1 000 Thus noise of only 5 mV repr...

Страница 13: ...tor Considerations Motor frames must also be grounded Motors must be grounded directly to the control and plant ground with as short a ground wire as possible Capacitive coupling within the motor wind...

Страница 14: ...igure 3 3 5 output voltage taps are provided to accommodate variations in incoming AC voltage Figure 3 3 Input Transformer Identification Phase Blank 3 Phase 3T E Single Phase T T Transformers XXX kVA...

Страница 15: ...logic and fan power 4 Connect the negative and positive wires from each servo motor to the terminal block as shown in the figure Figure 3 4 1 to 4 Axis Power Wiring 1 2 3 4 5 6 7 8 9 10 11 12 Axis 1 M...

Страница 16: ...o Test Point TP 1 and the lead to TP 6 Rotate the tachometer by hand and observe the VOM Clockwise rotation facing the shaft should cause a positive voltage measurement Figure 3 6 Input Signal Connect...

Страница 17: ...to pins 8 9 Or if you use normally closed switches connect these to pins17 18 2 Set jumper P1 for normally open or closed operation Note If Pl is in the left position normally closed and no limit swi...

Страница 18: ...urge current SC Indicator ON Refer to Section 5 Troubleshooting for corrective action The interlock function can be used to tie multiple servo control cards together locking all the cards together In...

Страница 19: ...Stop Some applications require a positive stop to disconnect the motor in the event of an emergency A relay with 4 sets of contacts can be connected as shown in Figure 3 10 to provide the E stop func...

Страница 20: ...3 10 Receiving Installation MN1213...

Страница 21: ...ow R Response Fully counterclockwise Low C Current Limit One turn clockwise Low B Balance Leave as shipped Center Note All pots have a 15 turn range and are without a hard stop You may hear a click wh...

Страница 22: ...terminal block 11 Verify that the Left and Right limit switches properly inhibit the axis travel in the direction defined 12 Slowly rotate the S pot clockwise to increase the motor shaft speed to full...

Страница 23: ...ing jumper P6 in its right most position pins 1 2 Refer to Figure 4 1 2 Set the T pot fully counterclockwise 3 Set the S pot fully clockwise Note If the pot A is used set it fully clockwise and pot S...

Страница 24: ...4 4 Adjustments Start Up MN1213...

Страница 25: ...isconnect power and wait for the bus voltage to bleed down to zero volts approximately 5 minutes Then carefully vacuum away any loose dirt or use clean compressed air can to blow away dust and dirt In...

Страница 26: ...wer before changing any fuse To change the fuse press the fuse holder cover to the side and lift up You will find a spare fuse underneath the main fuse Install the new fuse and press the cover down se...

Страница 27: ...supplier for alternatives Verify that adequate air circulation is present Check for overload using oscilloscope on the DCS line to determine current to motor 1 volt is approximately 1 10 of the peak...

Страница 28: ...5 4 Troubleshooting MN1213...

Страница 29: ...displacement C Competitor insulation displacement Quantity of UM3015H Control Cards Quantity of UM1506H Control Cards Chassis Including Power Supply UM Series UM X XXX Overvoltage Protection 1 Standar...

Страница 30: ...1 2 2 Operating Temp C 0 50 0 50 0 50 0 50 0 50 0 50 Weight lbs 14 14 20 6 20 6 25 25 Continuous Rating watts 250 250 500 500 500 500 Peak Rating W watts 2200 4000 4400 8000 4100 8000 Clamp Rating VDC...

Страница 31: ...Specifications Product Data 6 3 MN1213...

Страница 32: ...6 4 Specifications Product Data MN1213...

Страница 33: ...Specifications Product Data 6 5 MN1213 Dimensions Inches mm UM4 shown Height 7 25 184 15...

Страница 34: ...6 6 Specifications Product Data MN1213...

Страница 35: ...brate the servo control Resistors can be soldered to the module to select the upper limit values of the following Peak Current Continuous Current Foldback Current Figure A 1 Personality Module 10k 0 3...

Страница 36: ...4k 5 26 7k 12 10 2k 4 12 1k 11 6 81k 3 6 19k 10 4 99k 2 3 01k 9 3 65k 1 1 00k UM3015HS 100 150 30 OPEN 15 OPEN 28 14 0k 14 475k 26 8 87k 13 97 6k 24 6 19k 12 59 0k 22 4 64k 11 31 6k 20 3 57k 10 23 2k...

Страница 37: ...unction Jumper Identification P1 Normally closed limit circuit 3 2 1 ON OFF P2 Differential Input 3 2 1 OFF ON P3 Current monitor value DCS 3 2 1 Absolute Actual P4 EC Fault Function 3 2 1 Foldback La...

Страница 38: ...A 4 Product Overview MN1213...

Страница 39: ...d in USA 4 00 C J 2500 CH TEL 41 52 647 4700 FAX 41 52 659 2394 D TEL 49 89 90 50 80 FAX 49 89 90 50 8491 UK TEL 44 1342 31 5977 FAX 44 1342 32 8930 I TEL 39 11 562 4440 FAX 39 11 562 5660 AU TEL 61 2...

Страница 40: ...UM Series DC Servo Control MN1213...