Goodrive350-19 series VFD Function parameter list
- 256 -
Function
code
Name
Description
Default
value
Modify
2: Reserved
3: Forward/reverse rotation switch-over
4: Clear UP/DOWN setting
5: Coast to stop
6: Switch over the running command reference
mode in sequence
7: Reserved
Tens: Reserved
P07.03
Running
command channel
switch-over
sequence of
QUICK key
When P07.02=6, set the switch-over sequence of
running command channel.
0: keypad control
→terminal control→
communication control
1: keypad control
←→terminal control
2: keypad control
←→communication control
3: terminal control
←→communication control
0
○
P07.04
Stop function
selection of
STOP/RST key
Validness selection of stop function of STOP/RST.
For fault reset, STOP/RST is valid under any
situation.
0: valid only for panel control only
1: valid for both panel and terminal control
2: valid for both panel and communication control
3: valid for all control modes
0
○
P07.05
Displayed
parameter
selection 1 for
running state
0x0000
–0xFFFF
0x03FF
P07.06
Displayed
parameter
selection 2 for
running state
0x0000
–0xFFFF
0x0000