background image

UNI-Geräte E. Mangelmann Elektrotechnische Fabrik GmbH 

Holtumsweg 13, D-47652 Weeze, Tel. +49 2837/9134-0, Fax. +49 2837/1444 

www.uni-geraete.de  [email protected] 

Seite  1/9 

TM 4021 

220.100.040-09 

 

 
 

 

Solenoid Drive 

 

Series MG…X, MG…-A.X 

 

With  - protection for intended use in ex- zone 1 
 in accordance with 2014/34/EU (ATEX 95) 

 

 

Operating instructions      

                                                                                    (translation) 

 

Explosion protection 

The solenoid actuators and integrated solenoid  valve controllers conform to explosion protection type 
"de"  category  II2G  as  well  as  “td”  category  II2D  and  can  be  used  in  zones  in  which  explosive  gas, 
vapour,  mist,  or  air  and  dust mixtures may  occur,  i.e.  in  explosion  zone  1  and  21.  The  electrical  and 
thermal  parameters  of  the  separate  variants  can  be  obtained  from  the  respective  type  plates.  The 
explosion  protection  applies  to  operation  of  the  device.  For  installation,  maintenance  or  repairs,  it  is 
imperative that the relevant explosion protection regulations, especially EN 60079-14 (VDE 0165 T1), 
are  observed.  The  electrical  installation  work  must  be  carried  out  by,  or  under  the  supervision  of,  a 
skilled  electrician,  with  additional  observance  of  the  relevant  national  regulations  (VDE  0100  in 
Germany).  Prior  to  installation,  the  constraints  of  the  device  marking  must  be  compared  against  the 
envisaged operating conditions to ensure operation is as intended. 

 

Basics 

Valve – solenoid actuator – combinations are supplied fully assembled and tested as standard. When 
replacing or changing solenoid actuators, care should be taken that the combination with a UNI valve is 
approved and the magnet is properly secured to the valve (permissible tightening torque, for example). 
The device-specific serial  number for unequivocal identification  and the  year of build can be obtained 
from the type plate. 
Solenoid  actuators  are  electrotechnical  components  that  are  inoperative  without  the  associated  valve 
and  also  may  not  be  operated  for  themselves  alone!  For  outdoor  installations  always  use  solenoid 
actuators with a IP65 rating and a rain cover. Any solenoid actuators showing signs of damage are not 
to  be  installed  and  must  be  replaced.  If  the  solenoid  actuators  are  subject  to  external  loads  of  an 
exceptional  kind,  additional  protective  measures  are  to  be  taken  by  the  operator,  if  required.  Any 
undefined or unsuitable changes to the device may negatively influence the explosion protection and in 
the  worst  case  even  render  it  totally  ineffective.  UNI  devices  shall  accept  no  liability  for  any  loss  or 
damage (to the device/over and above this) which have been brought about by change(s) to the device. 
The same applies for claims under the warranty.    

 

Description of the device 

The solenoid actuator (pot magnet) is used as an actuating unit for valves. Constructionally the actuator 
consists of a magnet housing (tube, base, magnetic disk and lid), a coil and electronics. Depending on 
the version, the solenoid actuator may be operated with DC or AC voltage. The version that runs off AC 
voltage  has  a  built-in  rectifier.  Therefore  when  energised,  direct  current  flows  through  the  coils  of  all 
types.  The  solenoid  actuators  of  type  MG…X  have  a  conventional  coil  with  a  winding  and  resulting 
average  sustained  pickup  forces  with  average  current  consumption  in  continuous  operation.  The 
solenoid  actuators  of  type  MG…A.X  on  the  other  hand  have  two  windings  on  their  coil  body.  One 
pickup and one holding winding. The TS200 / TS900 / TS1500 built-in valve controller (rudimentary in 
"…A…" actuators) switches over after a defined time from the higher pickup power to the lesser holding 
winding power. In this way, very high pickup forces can be achieved short-term with simultaneous low 
current consumption in sustained (holding) operation. 
 
 
 
 
 
 
 
 

 
 

Содержание MG X Series

Страница 1: ...om the type plate Solenoid actuators are electrotechnical components that are inoperative without the associated valve and also may not be operated for themselves alone For outdoor installations alway...

Страница 2: ...nge clamping range of the cable gland must be noted and adhered to Where a flexible connecting line is used insulated wire end sleeves with plastic collars conforming to DIN 46228 part 4 are to be use...

Страница 3: ...may cause damage within the installation the user must possibly provide additional protective measures which go beyond the installed varistor Dismounting of the solenoid drive ATTENTION Disconnect th...

Страница 4: ...istor control TS and remove ex chamber cover 127 putting it onto a clear surface Loosen the cylinder head screw 910 1 and remove it with the lock washer 905 1 The magnet plate 500 may be removed from...

Страница 5: ...5 Solenoid drive MG x MG A x List of parts Item Qty Description 103 1 Solenoid housing 105 1 Solenoid housing cover 106 1 Upper part of housing 127 1 Ex chamber cover 403 1 O ring 500 1 Solenoid plate...

Страница 6: ...e housing 106 as well as Ex chamber cover 127 must be free of any defective parts or scratches The surfaces are to be greased with Kl berplex BE 31 502 grease On tightening of the cylinder head screw...

Страница 7: ...21 220 100 040 09 Solenoid Drive Series MG X MG A X With protection for intended use in ex zone 1 in accordance with 2014 34 EU ATEX 95 MG x MG A x with internal control in solenoid drive Solenoid val...

Страница 8: ...5 Max temperature of housing 95 C Ambient temperatur 20 C bis 60 C Fluid temperatur Solenoid core in fluid 20 C bis 60 C Solenoid core not in fluid no influence Duty cycle 100 Switching frequency Sole...

Страница 9: ...Holtumsweg 13 D 47652 Weeze Tel 49 2837 9134 0 Fax 49 2837 1444 www uni geraete de info uni geraete de Seite 9 9 TM 4021 220 100 040 09 Solenoid Drive Series MG X MG A X With protection for intended u...

Отзывы: