UNI Geräte MG X Series Скачать руководство пользователя страница 6

UNI-Geräte E. Mangelmann Elektrotechnische Fabrik GmbH 

Holtumsweg 13, D-47652 Weeze, Tel. +49 2837/9134-0, Fax. +49 2837/1444 

www.uni-geraete.de  [email protected] 

Seite  6/9 

TM 4021 

220.100.040-09 

 

 
 

 

Solenoid Drive 

 

Series MG…X, MG…-A.X 

 

With  - protection for intended use in ex- zone 1 
 in accordance with 2014/34/EU (ATEX 95) 

 

 

M10 

22 Nm 

M12 

39 Nm 

 

 Diamensions 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
    * Dimension for removing the solenoid drive 

 

 

 

 

The assembly is done in reversed order. 

 

 

ATTENTION! 

The metal contact and cleavage surfaces between the solenoid housing 
(103) and the upper part of the housing (106) as well as Ex-chamber 
cover (127) must be free of any defective parts or scratches. The 
surfaces are to be greased with Klüberplex BE 31-502 grease. 
On tightening of the cylinder head screw (910/1) the cleavage between 
ma- gnet plate (500) and upper part of the housing (106) must be 0,05 - 
0,1  mm.  This  dimension  is  to  be  determined  by  means  of  a  calliper 
gauge. 
The 4 cylinder head screws (910/3) have to be tightened with a torque of 
50Nm! 

 

 
 

NOTE! 

On mounting of the magnet plate (500) make sure that the dowel pins 
(943/1) and (943/2), will be punched into the magnet plate (500) to 
connect it to the upper part of the housing (106) and the solenoid housing 
(103). 

 
 

 

Torques pos. 910/1, 910/2 

Thread size 

Torque 

Thread size 

Torque 

 

M6 

4,6 Nm 

M8 

11 Nm 

 

Содержание MG X Series

Страница 1: ...om the type plate Solenoid actuators are electrotechnical components that are inoperative without the associated valve and also may not be operated for themselves alone For outdoor installations alway...

Страница 2: ...nge clamping range of the cable gland must be noted and adhered to Where a flexible connecting line is used insulated wire end sleeves with plastic collars conforming to DIN 46228 part 4 are to be use...

Страница 3: ...may cause damage within the installation the user must possibly provide additional protective measures which go beyond the installed varistor Dismounting of the solenoid drive ATTENTION Disconnect th...

Страница 4: ...istor control TS and remove ex chamber cover 127 putting it onto a clear surface Loosen the cylinder head screw 910 1 and remove it with the lock washer 905 1 The magnet plate 500 may be removed from...

Страница 5: ...5 Solenoid drive MG x MG A x List of parts Item Qty Description 103 1 Solenoid housing 105 1 Solenoid housing cover 106 1 Upper part of housing 127 1 Ex chamber cover 403 1 O ring 500 1 Solenoid plate...

Страница 6: ...e housing 106 as well as Ex chamber cover 127 must be free of any defective parts or scratches The surfaces are to be greased with Kl berplex BE 31 502 grease On tightening of the cylinder head screw...

Страница 7: ...21 220 100 040 09 Solenoid Drive Series MG X MG A X With protection for intended use in ex zone 1 in accordance with 2014 34 EU ATEX 95 MG x MG A x with internal control in solenoid drive Solenoid val...

Страница 8: ...5 Max temperature of housing 95 C Ambient temperatur 20 C bis 60 C Fluid temperatur Solenoid core in fluid 20 C bis 60 C Solenoid core not in fluid no influence Duty cycle 100 Switching frequency Sole...

Страница 9: ...Holtumsweg 13 D 47652 Weeze Tel 49 2837 9134 0 Fax 49 2837 1444 www uni geraete de info uni geraete de Seite 9 9 TM 4021 220 100 040 09 Solenoid Drive Series MG X MG A X With protection for intended u...

Отзывы: