Description

The door fan replacement kit contains parts required to install
1 door fan in E1h/E2h drives in IP21/IP54 enclosures.

Kit Ordering Number

Kit number

Kit description

176F6636

Door fan for E1h/E2h drives

Table 1.1 Ordering Number for the Door Fan Kit

Items Supplied

The door fan replacement kit contains the following:

1 fan

Installation instructions

Safety Instructions

Only qualified, Danfoss authorized personnel are allowed to
install the parts described in these installation instructions.
Handling of the drive and its parts must be done in
accordance with the corresponding 

operating guide

.

WARNING

ELECTRICAL SHOCK HAZARD

VLT

®

 FC series drives contain dangerous voltages when

connected to mains voltage. Improper installation, and
installing or servicing with power connected, can cause
death, serious injury, or equipment failure.

To avoid death, serious injury, or equipment failure:

Only use qualified electricians for the installation.

Disconnect the drive from all power sources before
installation or service.

Treat the drive as live whenever the mains voltage
is connected.

Follow the guidelines in these instructions and local
electrical safety codes.

WARNING

DISCHARGE TIME

The drive contains DC-link capacitors, which can remain
charged even when the drive is not powered. High voltage
can be present even when the warning LED indicator lights
are off. Failure to wait 40 minutes after power has been
removed before performing service or repair work can result
in death or serious injury.

Stop the motor.

Disconnect AC mains and remote DC-link power
supplies, including battery back-ups, UPS, and DC-
link connections to other drives.

Disconnect or lock PM motor.

Wait 40 minutes for capacitors to discharge fully.

Before performing any service or repair work, use
an appropriate voltage measuring device to make
sure that the capacitors are fully discharged.

Removing the Door Fan

The enclosure door includes 2 fan assemblies at the door top.
To remove and replace the door fan, use the following
procedures. Refer to 

Illustration 1.1

.

1.

Pinch together the release tabs on the front grill and
remove the grill from the enclosure door.

2.

Remove the fan filter.

3.

Inside the enclosure door, unplug the in-line
connector attaching the fan cable.

4.

Detach 4 screws (T20), 2 nuts, and 2 corner brackets
from the corners of the fan. When removing the
screws, hold each nut (7 mm) with a wrench on the
opposite side of the fan.

5.

Remove the fan from the enclosure door.

Installing the Door Fan

1.

Position the fan in the door of the enclosure. Check
that the air direction arrows point away from the
internal drive components when the door is closed.

2.

On the inner side of the door, replace the 2 brackets
at opposite corners of the fan and secure with 2
screws (T20).

Installation Instructions

Door Fan Replacement for E1h/E2h Drives
VLT

®

 FC Series FC 102, FC 103, FC 202, and FC 302

Danfoss A/S © 03/2018 All rights reserved.