TC1784
System Control Unit (SCU)
User´s Manual
3-142
V1.1, 2011-05
32-bit SCU, V1.18
WDT_CON1
WDT Control Register 1
(F000 05F4
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
r
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
DR
IR
0
CLR
IRF
r
rw
rw
r
rwh
Field
Bits
Type Description
CLRIRF
0
rwh
Clear Internal Reset Flag
This bit is used to request a clear of the internal flag
storing the information about the first WDT reset
request.
0
B
No action
1
B
Request to clear the internal flag
This bit can only be modified if WDT_CON0.ENDINIT
is cleared. The internal flag is cleared when ENDINIT
is set again. As long as ENDINIT is cleared, the
internal flag is unchanged and controls the current
past error status of the WDT. When ENDINIT is set
again with a Valid Modify Access, the internal flag is
cleared together with this bit.
IR
2
rw
Input Frequency Request Control Bit
0
B
Request to set input frequency to
f
FPI
/16384.
1
B
Request to set input frequency to
f
FPI
/256.
This bit can only be modified if WDT_CON0.ENDINIT
is cleared. WDT_SR.IS is updated by this bit only
when ENDINIT is set again. As long as ENDINIT is
cleared, WDT_SR.IS controls the current input
frequency of the Watchdog Timer. When ENDINIT is
set again, WDT_SR.IS is updated with the state of IR.
Summary of Contents for TC1784
Page 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Page 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Page 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...