Note: If a Message Buffer is configured for the dynamic segment and both bits of the
channel filtering field are set to 1, no Frames are transmitted resp. received
Frames are ignored (same function as CHA = CHB = 0)
Receive Buffers
Valid received Frames are stored if they are received on the channels specified in the
channel filtering field. Only in static segment a receive buffer may be setup for reception
on both channels (CHA and CHB set). Other filtering criteria must also be met.
If a valid Header Segment was stored, the respective MBC flag in the Message Buffer
Status Changed register is set. If a valid Payload Segment was stored, the respective
to
register is
set. In both cases, if bit
.
in the Header Section of the respective Message
Buffer is set, the RXI flag in the Status Service Request Register is set to 1. If enabled
an service request is generated.
Transmit Buffers
The content of the buffer is transmitted only on the channels specified in the channel
filtering field when the Frame ID filtering and cycle counter filtering criteria are also met.
Only in static segment a transmit buffer may be setup for transmission on both channels
(CHA and CHB set). After transmission has completed, and if bit
in the
Header Section of the respective Message Buffer is set, the TXI flag in the Status Service
Request Register is set to 1. If enabled an service request is generated.
20.6.7.3 Cycle Counter Filtering
Cycle counter filtering is based on the notion of a cycle set. For filtering purposes, a
match is detected if any one of the elements of the cycle set is matched. The cycle set
is defined by the cycle code field in the Header Section of each Message Buffer.
If Message Buffer 0 is configured to hold the startup / SYNC Frame or the single slot
Frame by bits TXST, TXSY, and TSM in the SUC Configuration Register 1, cycle counter
filtering for Message Buffer 0 should be disabled.
Note: Sharing of a static time slot via cycle counter filtering between different nodes of a
FlexRay™ network is
not
allowed.
The set of cycle numbers belonging to a cycle set is determined as described in
Summary of Contents for TC1784
Page 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Page 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Page 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...