TC1784
Synchronous Serial Interface (SSC)
User´s Manual
17-36
V1.1, 2011-05
SSC, V1.5
The Error Flag Modification Register EFM is required for clearing or setting the four error
flags which are located in register STAT.
EFM
Error Flag Modification Register
(2C
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
r
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
SET
BE
SET
PE
SET
RE
SET
TE
CLR
BE
CLR
PE
CLR
RE
CLR
TE
0
SET
PAR
E
0
CLR
PAR
E
w
w
w
w
w
w
w
w
r
w
r
w
Field
Bits
Type Description
CLRPARE
0
w
Clear Parity Error Flag
0
B
No effect
1
B
Bit STAT.PARE is cleared.
Bit is always read as 0.
SETPARE
4
w
Set Parity Error Flag
0
B
No effect
1
B
Bit STAT.PARE is set.
Bit is always read as 0.
CLRTE
8
w
Clear Transmit Error Flag
0
B
No effect
1
B
Bit STAT.TE is cleared.
Bit is always read as 0.
CLRRE
9
w
Clear Receive Error Flag
0
B
No effect
1
B
Bit STAT.RE is cleared.
Bit is always read as 0.
CLRPE
10
w
Clear Phase Error Flag
0
B
No effect
1
B
Bit STAT.PE is cleared.
Bit is always read as 0.
Summary of Contents for TC1784
Page 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Page 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Page 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...