TC1784
FlexRay™ Protocol Controller (E-Ray)
User´s Manual
20-216
V1.1, 2011-05
E-Ray, V3.13
If after the first double-cycle less than two valid startup Frames are received within an
even cycle, or less than two valid Startup Frame pairs are received within a double-cycle,
the startup attempt is aborted.
Nodes in this state need to see two valid Startup Frame pairs for two consecutive double-
cycles each to be allowed to leave STARTUP and enter NORMAL_OPERATION.
Consequently, they leave startup at least one double-cycle after the node that initiated
the coldstart and only at the end of a cycle with an odd cycle number.
20.6.5.9 NORMAL_ACTIVE State
As soon as the node that transmitted the first CAS symbol (resolving the potential access
conflict and entering “STARTUP” via coldstart path) and one additional node have
entered the “NORMAL_ACTIVE” state, the startup phase for the cluster has finished. In
the “NORMAL_ACTIVE” state, all configured messages are scheduled for transmission.
This includes all Data Frames as well as the SYNC Frames. Rate and offset
measurement is started in all even cycles (even/odd cycle pairs required).
In “NORMAL_ACTIVE” state the Communication Controller supports regular
communication functions
•
The Communication Controller performs transmissions and reception on the
FlexRay™ bus as configured
•
Clock synchronization is running
•
The Host interface is operational
The Communication Controller exits from that state to
•
“HALT” state by writing
= 0110
B
(HALT command, at the end of the
current cycle)
•
“HALT” state by writing
B
(FREEZE command, immediately)
•
“HALT” state due to change of the error state from “ACTIVE” to “COMM_HALT”
•
“NORMAL_PASSIVE” state due to change of the error state from “ACTIVE” to
“PASSIVE”
•
“READY” state by writing
= 0010
B
(READY command)
20.6.5.10 NORMAL_PASSIVE State
“NORMAL_PASSIVE” state is entered from “NORMAL_ACTIVE” state when the error
state changes from ACTIVE (green) to PASSIVE (yellow).
In “NORMAL_PASSIVE” state, the node is able to receive all Frames (node is fully
synchronized and performs clock synchronization). In comparison to the
“NORMAL_ACTIVE” state the node does not actively participate in communication, i.e.
neither symbols nor Frames are transmitted.
Summary of Contents for TC1784
Page 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Page 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Page 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...