![Infineon Technologies TC1784 User Manual Download Page 1625](http://html.mh-extra.com/html/infineon-technologies/tc1784/tc1784_user-manual_20554461625.webp)
TC1784
FlexRay™ Protocol Controller (E-Ray)
User´s Manual
20-249
V1.1, 2011-05
E-Ray, V3.13
(word 3)
Read access via MBS, updated by the Communication Controller at the end of the
configured slot.
•
VFRA: Valid Frame Received on channel A
•
VFRB: Valid Frame Received on channel B
•
SEOA: Syntax Error Observed on channel A
•
SEOB: Syntax Error Observed on channel B
•
CEOA: Content Error Observed on channel A
•
CEOB: Content Error Observed on channel B
•
SVOA: Slot boundary Violation Observed on channel A
•
SVOB: Slot boundary Violation Observed on channel B
•
TCIA: Transmission Conflict Indication channel A
•
TCIB: Transmission Conflict Indication channel B
•
ESA: Empty Slot Channel A
•
ESB: Empty Slot Channel B
•
MLST: Message LoST
•
FTA: Frame Transmitted on Channel A
•
FTA: Frame Transmitted on Channel B
•
Cycle Count Status: Actual cycle count when status was updated
•
RCIS: Received on CHannel Indicator Status
•
SFIS: Startup Frame Indicator Status
•
SYNS: SYNC Frame Indicator Status
•
NFIS: NULL Frame Indicator Status
•
PPIS: Payload Preamble Indicator Status
•
RESS: Reserved Bit Status
20.6.12.2 Data Partition
The Data Partition of the Message RAM stores the Data Sections of the Message Buffers
configured for reception / transmission as defined in the Header Partition. The number
of data bytes for each Message Buffer can vary from 0 to 254. To optimize the data
transfer between the shift registers of the two FlexRay™ Protocol Controllers and the
Message RAM as well as between the Host interface and the Message RAM, the
physical width of the Message RAM is set to 4 bytes.
The Data Partition starts after the last word of the Header Partition. When configuring the
Message Buffers in the Message RAM the programmer has to assure that the data
pointers point to addresses within the Data Partition.
below shows an
example how the Data Sections of the configured Message Buffers can be stored in the
Data Partition of the Message RAM.
The beginning and the end of a Message Buffer’s Data Section is determined by the data
pointer and the payload length configured in the Message Buffer’s Header Section,
Summary of Contents for TC1784
Page 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Page 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Page 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...