FIFO Critical Level (FCL)
The Communication Controller accepts modifications of the register in
“DEFAULT_CONFIG” or “CONFIG” state only.
FCL
FIFO Critical Level
(030C
H
)
Reset Value: 0000 0080
H
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
0
CL
r
rw
Field Bits
Type Description
CL
[7:0]
rw
Critical Level
When the receive FIFO fill level FSR.RFFL is equal or greater than
the critical level configured by CL, the receive FIFO critical level
flag FSR.RFCL is set. If CL is programmed to values > 128, bit
FSR.RFCL is never set. When FSR.RFCL changes from 0 to 1 bit
is set to 1, and if enabled, a service request is
generated.
0
[31:8] r
Reserved