TC1784
Micro Link Interface (MLI)
User´s Manual
22-103
V1.1, 2011-05
MLI, V2.0
CMDP2
[19:16]
rw
Command Code for Pipe 2
This bit field contains the command code related to
pipe 2. The pipe 2 command codes allow to control the
MLI receiver in the receiving controller.
0001
B
Enable Automatic Data Mode (RCR.MOD = 1)
0010
B
Disable Automatic Data Mode (RCR.MOD = 0)
0100
B
Clear bit TRSTATR.RP0
0101
B
Clear bit TRSTATR.RP1
0110
B
Clear bit TRSTATR.RP2
0111
B
Clear bit TRSTATR.RP3
1111
B
Activate a pulse at BRKOUT
Other bit combinations are reserved for future use; no
further action in the receiver.
CMDP3
[27:24]
rw
Command Code for Pipe 3
This bit field contains the command code related to
pipe 3. The command codes for pipe 3 are free
programmable by software.
0
[7:4],
[15:12],
[23:20],
[31:28]
r
Reserved
Read as 0; should be written with 0.
Field
Bits
Type Description