TC1784
Synchronous Serial Interface (SSC)
User´s Manual
17-34
V1.1, 2011-05
SSC, V1.5
The Status Register STAT contains status flags for error identification, the busy flag, and
a bit field that indicates the current shift counter status.
0
13,
[31:20]
r
Reserved
Read as 0; should be written with 0.
STAT
Status Register
(28
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
r
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
BSY BE
PE
RE
TE
0
PAR
R
VAL
PAR
T
VAL
PAR
E
BC
r
rh
rh
rh
rh
rh
r
rh
rh
rh
rh
Field
Bits
Type Description
BC
[3:0]
rh
Bit Count Status
BC indicates the current status of the shift counter. The
shift counter is updated with every shifted bit.
PARE
4
rh
Parity Error Flag
0
B
No error
1
B
Received parity bit is wrong.
PARTVAL
5
rh
Parity Transmit Value
If parity mode is enabled, this bit indicates the
calculated parity bit for the transmission of the actual
serial frame. PARTVAL is written with the transmit
parity value when the shift register is loaded from TB.
PARTVAL is reset when CON.PAREN is reset.
PARRVAL
6
rh
Parity Receive Value
if parity mode is enabled, this bit PARRVAL is loaded
when the received data is written into RB. PARRVAL is
reset when CON.PAREN is reset.
Field
Bits
Type Description
Summary of Contents for TC1784
Page 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Page 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Page 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...