TC1784
LMB External Bus Unit
User´s Manual
12-59
V1.1, 2011-05
EBUT13L-A, V1.16
12.11.7
Bus Read Access Parameter Register, BUSRAPx
EBU_BUSRAPx (x = 0-3)
EBU Bus Read Access Parameter Register
(02C
H
+x*10
H
)
Reset Value: FFFF FFFF
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
ADDRC
AHOLDC
CMDDELAY
EXTDATA
EXTCLOCK
rw
rw
rw
rw
rw
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
DATAC
WAITRDC
RDRECOVC
RDDTACS
rw
rw
rw
rw
Field
Bits
Type Description
RDDTACS
3:0
rw
Recovery Cycles between Different Regions
This bit field determines the number of clock cycles of
the Recovery Phase between consecutive accesses
directed to different regions or different types of
access. See
0000
B
No Recovery Phase clock cycles available.
0001
B
1 clock cycle selected.
…
B
…
1110
B
14 clock cycles selected.
1111
B
15 clock cycles selected.
RDRECOVC
6:4
rw
Recovery Cycles after Read Accesses
This bit field determines the basic number of clock
cycles of the Recovery Phase at the end of read
accesses.
000
B
No Recovery Phase clock cycles available.
001
B
1 clock cycle selected.
…
B
…
110
B
6 clock cycles selected.
111
B
7 clock cycles selected.
Summary of Contents for TC1784
Page 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Page 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Page 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...