![Infineon Technologies TC1784 User Manual Download Page 1132](http://html.mh-extra.com/html/infineon-technologies/tc1784/tc1784_user-manual_20554461132.webp)
TC1784
Synchronous Serial Interface (SSC)
User´s Manual
17-11
V1.1, 2011-05
SSC, V1.5
Note: In Master Mode, the Transmit Buffer register TB is loaded with new data for the
following transmission just at the end of the current transmission and a leading
delay > 0 is selected (SSOTC.LEAD not equal 00
B
), a slightly enlarged leading
delay (< one SCLK shift clock period) is generated for the following transmission.
17.1.2.5 Parity Mode
The SSC allows to add a parity bit to a serial frame. The parity mode can be enabled
individually for frame transmission (CON.PARTEN) and frame reception
(CON.PARREN). The type of parity (even/odd parity) can be selected, valid for transmit
and receive parity.
If transmit parity is enabled (CON.PARTEN = 1), the shift register is loaded for a frame
transmission by the content of the Transmit Buffer TB, the parity bit becomes calculated
and stored in STAT.PARTVAL. Depending on bit CON.HB, the parity bit preceeds or
follows the transmitted data bits.
If receive parity is enabled (CON.PARREN = 1) and the last bit of a frame has been
received, the received data of the frame is stored in RB and the received parity bit is
stored in STAT.PARRVAL. The received and calculated parity bits are now compared.
If this comparison fails, a parity error is detected and the error status flag STAT.PARE is
set. If enabled by bit CON.PAREEN, a parity error activates the error interrupt request
line EIR.
shows how a parity bit is added to the transmitted data bits of a frame. The
number of the transmitted bits of a complete frame remains constant without or with
parity, assuming that COM.BM is not changed. Therefore, the number of transmitted
data bits is reduced by one bit when parity mode is enabled.
If the heading control bit CON.HB = 0 (LSB first), the parity bit preceeds the data bits in
parity mode and is transmitted as the first bit of a frame. If the heading control bit
CON.HB = 1 (MSB first), the parity bit follows the data bits in parity mode and is
transmitted as the last bit of a frame.
Summary of Contents for TC1784
Page 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Page 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Page 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...