TC1784
General Purpose Timer Array (GPTA
®
v5)
User´s Manual
21-23
V1.1, 2011-05
GPTA
®
v5, V1.14
Positioning System With Two Sensors
The 2-sensor Mode is enabled when bit PDLCTR.TSEx is reset. The sensors are
mounted at a 90
°
angle to each other (see
). The third sensor input of the
PDL cell is internally disabled and DCM1/DCM3 cell inputs are driven by fed-through
FPC2/FPC5 output lines.
This configuration can measure an absolute position with a resolution of 90
°
. No error
conditions can be detected.
Figure 21-13 Interface Signals of a PDL in a 2-Sensor Positioning System
illustrates how the output signals of a 2-sensor system superimposed with
noise are processed by the PDL cell. Jitter pulses are completely compensated if they
do not occur on both signal lines simultaneously.
!
Means not
Re
Means rising edge
Fe
Means falling edge
Forward
ReS1*!S2 + S1*ReS2 + FeS1*S2 + !S1*FeS2
Backward
ReS1*S2 + !S1*ReS2 + FeS1*!S2 + S1*FeS2
Position
Forward_Counter - Backward_Counter
MCT05922
S1
S2
Forward
Backward
S2
Forward_Counter
Backward_Counter
Forward
S1
S2
Backward
S1
Summary of Contents for TC1784
Page 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Page 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Page 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...