GTU Configuration Register 6 (GTUC06)
The Communication Controller accepts modifications of the register in
“DEFAULT_CONFIG” or “CONFIG” state only.
GTUC06
GTU Configuration Register 6
(00B4
H
)
Reset Value: 0002 0000
H
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
0
MOD
0
ASR
r
rw
r
rw
Field Bits
Type Description
ASR
[10:0]
rw
Accepted Startup Range
1)
(pdAcceptedStartupRange)
Number of Microticks constituting the expanded range of
measured deviation for startup Frames during integration. Valid
values are 0 to 1875 (0
H
to 753
H
) Microticks.
1) This bit can be updated in “DEFAULT_CONFIG” or “CONFIG” state only!
MOD
[26:16] rw
Maximum Oscillator Drift
(pdMaxDrift)
Maximum drift offset between two nodes that operate with
unsynchronized clocks over one communication cycle in
Microticks. Valid values are 2 to 1923 (2
H
to 783
H
) Microticks.
0
[15:11],
[31:27]
r
Reserved
Returns 0 if read; should be written with 0.
Summary of Contents for TC1784
Page 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Page 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Page 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...