![Infineon Technologies TC1784 User Manual Download Page 1965](http://html.mh-extra.com/html/infineon-technologies/tc1784/tc1784_user-manual_20554461965.webp)
TC1784
Micro Link Interface (MLI)
User´s Manual
22-16
V1.1, 2011-05
MLI, V2.0
22.1.2.6 Optimized Read Frame
An Optimized Read Frame is used by the Local Controller to request 8-bit, 16-bit, or 32-
bit wide data from the Remote Controller without sending any offset address. The
address for the requested data can be predicted and calculated by the MLI receiver of
the Remote Controller.
The Optimized Read Frame contains the following parts:
•
Header:
The header starts with frame code FC = 11
B
followed by the pipe number PN of the
Transfer Window that has been the target of the read operation.
•
Data Width DW:
The data width DW indicates if the read from the Transfer Window was a 8-bit, 16-
bit, or 32-bit read action. It defines how many bytes have to be delivered to the Local
Controller by the Answer Frame. Same coding as for the Discrete Read Frame.
•
Parity bit P
Figure 22-13 Optimized Read Frame
More details about the Optimized Read Frame handling of the MLI module are provided
on
.
MCA06300_mod
1
0
2
DW
4
6
3
1
5
1
DW = Data width
Header
PN
P
Summary of Contents for TC1784
Page 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Page 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Page 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...