![Infineon Technologies TC1784 User Manual Download Page 2232](http://html.mh-extra.com/html/infineon-technologies/tc1784/tc1784_user-manual_20554462232.webp)
TC1784
Analog to Digital Converter (ADC)
User´s Manual
23-126
V1.1, 2011-05
ADC, V1.3
TROEN
21
rw
Trigger Option Enable
This bit selects the scan mode behavior of the
external multiplexer (if enabled).
Description see
.
0
B
Single-input scan is selected. The trigger
option is disabled (no automatic trigger of
more conversions of CHx).
1
B
Multi-input scan is selected. The trigger option
is enabled leading to an automatic scan
through the externally connected multiplexer
inputs by automatically triggering additional
conversions of CHx until EMUX = 0.
SCANEN
22
rw
Scan Enable
This bit enables/disables the automatic scan of the
inputs of the external multiplexer for conversions of
the channel selected by bit field EMUXCHNR (taken
into account only if EMUXEN=1).
0
B
The scan mode is disabled. Bit field EMUX is
updated by bit field SETEMUX at the
beginning of a conversion of the selected
channel. If bit EMUX is changed, the value of
EMSAMPLE is applied.
1
B
The scan mode is enabled. Bit field EMUX is
decremented by 1 for each conversion of the
selected channel. After reaching 0, bit field
EMUX is updated by bit field SETEMUX.
The value of EMSAMPLE is always applied for
the selected channel.
It is recommended to write the start value of
the first scan sequence to SETEMUX while
EMUXEN=0.
Field
Bits
Type Description
Summary of Contents for TC1784
Page 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Page 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Page 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...