3.2.12.2 Configuration Registers
Reset Counter Control Register
This register controls the reset length settings for the three resets.
CB0
18
rh
Reset Request Trigger Reset Status for Cerberus
System Reset
0
B
The last reset was not requested by this reset
trigger
1
B
The last reset was requested by this reset
trigger
CB1
19
rh
Reset Request Trigger Reset Status for Cerberus
Debug Reset
0
B
The last reset was not requested by this reset
trigger
1
B
The last reset was requested by this reset
trigger
CB3
20
rh
Reset Request Trigger Reset Status for Cerberus
Application Reset
0
B
The last reset was not requested by this reset
trigger
1
B
The last reset was requested by this reset
trigger
TP
21
rh
Reset Request Trigger Reset Status for TP
0
B
The last reset was not requested by this reset
trigger
1
B
The last reset was requested by this reset
trigger
0
2,
[15:5],
[31:22]
r
Reserved
Read as 0; should be written with 0.
Field
Bits
Type
Description
Summary of Contents for TC1784
Page 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Page 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Page 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...