![Infineon Technologies TC1784 User Manual Download Page 1455](http://html.mh-extra.com/html/infineon-technologies/tc1784/tc1784_user-manual_20554461455.webp)
TC1784
FlexRay™ Protocol Controller (E-Ray)
User´s Manual
20-79
V1.1, 2011-05
E-Ray, V3.13
Timer 1 Configuration (T1C)
Relative timer. After the specified number of Macroticks has expired, the timer 1 service
request is asserted, output signal TINT1SR is set to 1 for the duration of one Macrotick
and SIR.TI1 is set to 1.
Timer 1 can be activated as long as the POC is either in “NORMAL_ACTIVE” state or in
“NORMAL_PASSIVE” state. Timer 1 is deactivated when leaving “NORMAL_ACTIVE”
state or “NORMAL_PASSIVE” state except for transitions between the two states.
Before reconfiguration of the timer, the timer has to be halted first by resetting bit T1RC
to 0.
T1C
Timer 1 Configuration
(0048
H
)
Reset Value: 0002 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
T1MC
r
rw
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
T1M
S
T1R
C
r
rw
rwh
Field Bits
Type Description
T1RC
0
rwh
Timer 1 Run Control
0
B
Timer 1 halted
1
B
Timer 1 running
T1MS
1
rw
Timer 1 Mode Select
0
B
Single-shot mode
1
B
Continuous mode
T1MC
[29:16] rw
Timer 1 Macrotick Count
When the configured Macrotick count is reached the timer 1
service request is generated.
Valid values are:
2
H
…3FFF
H
Macroticks in continuous mode
1
H
…3FFF
H
Macroticks in single-shot mode
0
[15:2],
[31:30]
r
Reserved
Returns 0 if read; should be written with 0.
Summary of Contents for TC1784
Page 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Page 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Page 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...