The
START
softkey activates the window for manually entering the start frequency.
The allowed range of values for the start frequency is:
0 Hz
≤
f
start
≤
f
max
- minspan
Remote command:
FREQ:STAR 20MHz
STOP
The
STOP
softkey activates the window for entering the stop frequency.
The allowed range of values for the stop frequency is:
minspan
≤
f
stop
≤
f
max
Remote command:
FREQ:STOP 2000MHz
FREQUENCY
OFFSET
The
FREQUENCY OFFSET
softkey activates the window for entering an arithmeti-
cal frequency offset which is added to the frequency axis labelling. The allowed
range of values for the offset is -100 GHz to 100 GHz. The default setting is 0 Hz.
Remote command:
FREQ:OFFS 10 MHz
SIGNAL
TRACK
The
SIGNAL TRACK
softkey switches on the tracking of a signal near the center fre-
quency. The signal is tracked as long it is in the search bandwidth around the center
frequency defined with
TRACK BW
and above the level threshold defined with
TRACK THRESHOLD
.
For that purpose, the maximum signal is searched (
PEAK SEARCH)
on the screen
and the center frequency set to this signal (
MARKER
->
CENTER
) after each fre-
quency sweep within the search bandwidth.
If the signal falls below the level threshold or jumps out of the search bandwidth
around the center frequency, the center frequency is not varied until a signal is in the
search bandwidth above the level threshold. This can be achieved by manually
modifying the center frequency, for example.
On switching on, the softkey is highlighted and the search bandwidth and the thresh-
old value are marked on the diagram by two vertical lines and one horizontal line. All
these lines are provided with the designation TRK.
At the same time a submenu is opened in which the search bandwidth, the threshold
value and the trace can be modified for the maximum search.
The softkey is only available in the frequency domain (span >0).
Remote command:
CALC:MARK:FUNC:STR OFF
TRACK (ON
OFF)
The
TRACK (ON OFF)
softkey switches on and off signal tracking.
Remote command:
CALC:MARK:FUNC:STR OFF
f
start
start
frequency
minspan smallest selectable span (10 Hz)
f
max
max.
frequency
f
stop
stop
frequency
minspan smallest selectable span (10 Hz)
f
max
max.
frequency
Summary of Contents for R&S FSP Series
Page 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Page 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Page 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Page 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Page 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Page 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Page 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...