![Rohde & Schwarz R&S FSP Series Operating Manual Download Page 179](http://html.mh-extra.com/html/rohde-and-schwarz/rands-fsp-series/rands-fsp-series_operating-manual_1477864179.webp)
Operating Manual 1164.4556.12 - 06
4.107
R&S FSP
Instrument Functions
Analyzer Mode
Fig. 4.13 Display of the complementary cumulative distribution function (CCDF)
Alternate to the histogram display of the APD the Complementary Cumulative Distri-
bution Function (CCDF) can be displayed. It shows the probability of an amplitude
exceeding a specific value.
For the APD function the x-axis is scaled in absolute values in dBm, whereas for the
CCDF function the x-axis is scaled relative to the MEAN POWER measured.
Definitions:
Crest factor = peak voltage to rms
CCDF = complementary cumulative distribution function
During an active statistic measurement, the functions FULL SCREEN,
SPLIT SCREEN and selection of the active diagram via the SCREEN A / SCREEN
B hotkeys are disabled.