Operating Manual 1164.4556.12 - 06
6.5.6.2
CALCulate:MARKer:FUNCtion Subsystem
The measurement window is selected by CALCulate 1 (screen A) or 2 (screen B).
CALCulate<1|2>:MARKer<1...4>:FUNCtion:CENTer
This command sets the center frequency of the selected measurement window equal to the frequency
of the indicated marker.
If marker 2, 3 or 4 is selected and used as delta marker, it is switched to the marker mode.
Example:
"CALC:MARK2:FUNC:CENT"
'Sets the center frequency of screen A to the frequency of marker 2.
Characteristics:
*RST value: -
SCPI: device-specific
Mode:
A-F
This command is an "event" and therefore has no *RST value and no query.
CALCulate<1|2>:MARKer<1...4>:FUNCtion:CSTep
This command sets the step width of the center frequency in the selected measurement window to the
X value of the current marker.
If marker 2, 3 or 4 is selected and used as delta marker, it is switched to the marker mode.
Example:
"CALC2:MARK3:FUNC:CST"
'Sets the center frequency of screen B to the same value as the frequency of
marker 3.
Characteristics:
*RST value: -
SCPI: device-specific
Mode:
A-F
This command is an event and therefore has no *RST value and no query.
CALCulate<1|2>:MARKer<1...4>:FUNCtion:DEModulation:CONTinuous
ON | OFF
This command switches on or off the continuous demodulation in the frequency domain (span >0) in
the selected measurement window. Thus acoustic monitoring of the signals can be performed in the
frequency domain. The function does not depend on the selected marker, i.e. the numeric suffix <1...4>
is irrelevant.
The command is only available with option audio demodulator R&S FSP-B3.
Example:
"CALC2:MARK3:FUNC:DEM:CONT ON"
'Switches on the continuous demodulation in screen B.
Characteristics:
*RST value: OFF
SCPI: device-specific
Mode:
A
Summary of Contents for R&S FSP Series
Page 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Page 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Page 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Page 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Page 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Page 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Page 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...