![Rohde & Schwarz R&S FSP Series Operating Manual Download Page 454](http://html.mh-extra.com/html/rohde-and-schwarz/rands-fsp-series/rands-fsp-series_operating-manual_1477864454.webp)
R&S FSP
Remote Control – Description of Commands
CALCulate Subsystem
6.60
Operating Manual 1164.4556.12 - 06
TRACE 1 of the selected screen is always used by the function. The suffix of MARKer will be ignored.
Example:
"DISP:WIND:TRAC:Y:RLEV –10dBm"
'Sets the reference level to 10 dBm
"INP:ATT 30 dB"
'Sets the input attenuation to 30 dB
"FREQ:CENT 935.2MHz;SPAN 0Hz"
'Sets the receive frequency to 935.2 MHz and the span to 0 Hz
"BAND:RES 1MHz;VID 3MHz"
'Sets the resolution bandwidth to 1 MHz and the video bandwidth to 3 MHz
"DET RMS"
'Sets the RMS detector
"TRIG:SOUR VID;LEV:VID 50 PCT"
'Selects the trigger source VIDeo and sets the level of the video trigger source to
50 PCT
"SWE:TIME 50ms"
'Sets the sweep time to 50 ms
"INIT;*WAI"
'Starts the measurement with synchronization
"CALC:MARK:FUNC:MSUM? 50US,450US,576.9US,8"
'Queries 8 bursts with an offset of 50 µs, a test time of 450 µs and a period of
576.9 µs
Characteristics:
*RST value: -
SCPI: device-specific
Mode:
A-T
This command is only available from firmware version 1.30 on.
t
Trace start
Time offset of
first pulse
Measurement
Time
Measurement
Time
Measurement
Time
Period
Period
P
Summary of Contents for R&S FSP Series
Page 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Page 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Page 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Page 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Page 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Page 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Page 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...