R&S FSP
Remote Control – Description of Commands
CALCulate Subsystem
6.68
Operating Manual 1164.4556.12 - 06
CALCulate<1|2>:MARKer<1...4>:FUNCtion:HARMonics:PRESet
This command optimizes the device settings depending on the mode in which the harmonic
measurement was started:
If the harmonic measurement was started in the frequency domain (span > 0), the frequency and the
level of the first harmonic are calculated, from which the measurement list is set up.
If the measurement was started in the time domain (span = 0), the frequency of the first harmonic is
not changed. The level, however, is not calculated.
The function is independent of the marker selection, i.e. the suffix
<1|2>
or
<1...4>
of
CALCulate
or
MARKer
is irrelevant.
Example:
"CALC:MARK:FUNC:HARM:PRES"
'Optimizes the device setting for the measurement of harmonics.
Characteristics:
*RST value: --
SCPI: device-specific
This command is an event and therefore has no *RST value and no query.
Mode:
A-F, A-T
CALCulate<1|2>:MARKer<1...4>:FUNCtion:HARMonics[:STATe]
ON | OFF
This command switches on or off the measurement of the harmonics of a carrier signal. The carrier
signal is the first harmonic. The function is independent of the marker selection, i.e. the suffix
<1|2>
or
<1...4>
of
CALCulate
or
MARKer
is irrelevant. It is only available in the frequency domain (span >
0).
If the measurement is started in the frequency domain (span > 0), the last span will define the search
range for the first harmonic. The level for the first harmonic will also be calculated in the frequency
domain. However, the measurement can also be started in the time domain (span = 0), in which case
the center frequency and the level used will remain unchanged.
Example:
"CALC:MARK:FUNC:HARM ON"
'Switches on the measurement of harmonics.
Characteristics:
*RST value: OFF
SCPI: device-specific
Mode:
A-F^
Summary of Contents for R&S FSP Series
Page 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Page 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Page 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Page 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Page 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Page 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Page 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...