![Rohde & Schwarz R&S FSP Series Operating Manual Download Page 586](http://html.mh-extra.com/html/rohde-and-schwarz/rands-fsp-series/rands-fsp-series_operating-manual_1477864586.webp)
R&S FSP
Remote Control – Description of Commands
SENSe Subsystem
6.192
Operating Manual 1164.4556.12 - 06
[SENSe<1|2>:]POWer:ACHannel:FILTer:ALPHa:CHANnel<1...12>
0…1
This command sets the rolloff factor of the RRC weighting filter for the TX channel. It is only available
if Fast ACP is not active and no predefine standard is selected.
Example:
"POW:ACH:FILT:ALPH:CHAN 0.26"
'sets Alpha to 0.26
Characteristics:
*RST value: 0.22
SCPI: device-specific
Mode:
A
[SENSe<1|2>:]POWer:ACHannel:FILTer:STATe:ACHannel
ON | OFF
This command switches the weigthing filter state for the adjacent channel on or off. It is only available
if Fast ACP is not active and no predefine standard is selected.
This command changes the setting for the alternate channels as well.
Example:
"POW:ACH:FILT:STAT:ACH ON"
’activates the weighting filter
Characteristics:
*RST value: OFF
SCPI: device-specific
Mode:
A
[SENSe<1|2>:]POWer:ACHannel:FILTer:STATe:ALL
ON | OFF
This command switches the weigthing filter state for TX channel, adjacent channel and all alternate
channels on or off. It is only available if Fast ACP is not active and no predefine standard is selected.
Example:
"POW:ACH:FILT:STAT:ALL ON"
'activates weighting filters for all channels
Characteristics:
*RST value: OFF
SCPI: device-specific
Mode:
A
[SENSe<1|2>:]POWer:ACHannel:FILTer:STATe:ALTernate<1...11>
ON | OFF
This command switches the weigthing filter state for the alternate channel on or off. It is only available
if Fast ACP is not active and no predefine standard is selected.
This command changes the setting for all alternate channels and for the adjacent channel as well. The
numeric suffixes at ALTernate are irrelevant for this command.
Example:
"POW:ACH:FILT:STAT:ALT ON"
'activates weighting filter
Characteristics:
*RST value: OFF
SCPI: device-specific
Mode:
A
Summary of Contents for R&S FSP Series
Page 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Page 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Page 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Page 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Page 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Page 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Page 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...