![Rohde & Schwarz R&S FSP Series Operating Manual Download Page 769](http://html.mh-extra.com/html/rohde-and-schwarz/rands-fsp-series/rands-fsp-series_operating-manual_1477864769.webp)
Operating Manual 1164.4556.12 - 06
8.5
R&S FSP
Maintenance and Instrument Interfaces
Instrument Interfaces
Addressed Commands
The addressed commands are encoded 00 - 0F hex. They are only effective for
instruments addressed as listeners.
Instrument Messages
Instrument messages are transferred on the data lines of the GPIB if the "ATN"
control line is not active. ASCII code is used.
Structure and syntax of the instrument messages are described in chapter
. The commands are listed and explained in detail in chapter
“Remote Control – Description of Commands”
8.3.2
Printer Interface (LPT)
The instrument is equipped with a 25-pin LPT connector on the rear panel for con-
necting a printer. In
the pin assignment is described. The LPT interface is
compatible with the CENTRONICS printer interface.
Fig. 8.2 LPT connector pin assignment
Command
QuickBASIC command
Effect on the instrument
DCL (Device Clear)
IBCMD (controller%, CHR$(20))
Aborts the processing of the commands just received
and sets the command processing software to a
defined initial state. Does not change the instrument
settings.
IFC (Interface Clear)
IBSIC (controller%)
Resets the interfaces to the default setting.
LLO (Local Lockout)
IBCMD (controller%, CHR$(17))
The LOC/IEC ADDR key is disabled.
SPE (Serial Poll Enable)
IBCMD (controller%, CHR$(24))
Ready for serial poll.
SPD (Serial Poll Disable)
IBCMD (controller%, CHR$(25))
End of serial poll.
PPU (Parallel Poll Unconfigure)
IBCMD (controller%, CHR$(21))
End of the parallel-poll state.
Command
QuickBASIC command
Effect on the instrument
SDC (Selected Device Clear)
IBCLR (device%)
Aborts the processing of the commands just received and sets
the command processing software to a defined initial state. Does
not change the instrument setting.
GTL (Go to Local)
IBLOC (device%)
Transition to the "Local" state (manual operation).
PPC (Parallel Poll Configure)
IBPPC (device%, data%)
Configure instrument for parallel poll. Additionally, the
QuickBASIC command executes PPE/PPD.
1
14
13
25
D0
D1
D2
D3
D4
D5
D6
D7
ACK
BUSY
PE
SELECT
STROBE
AUTOFEED
ERROR
INIT
SELECT IN
GND
GND
GND
GND
GND
GND
GND
GND
Summary of Contents for R&S FSP Series
Page 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Page 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Page 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Page 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Page 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Page 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Page 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...