![Rohde & Schwarz R&S FSP Series Operating Manual Download Page 144](http://html.mh-extra.com/html/rohde-and-schwarz/rands-fsp-series/rands-fsp-series_operating-manual_1477864144.webp)
R&S FSP
Instrument Functions
Analyzer Mode
4.72
Operating Manual 1164.4556.12 - 06
NEXT MIN
RIGHT
The
NEXT MIN RIGHT
softkey sets the active marker/delta marker to the next
higher minimum right of the current marker position on the selected trace.
Remote command:
CALC:MARK:MIN:RIGH
CALC:DELT:MIN:RIGH
NEXT MIN
LEFT
The
NEXT MIN LEFT
softkey sets the active marker/delta marker to the next higher
minimum left of the current marker position on the selected trace.
Remote command:
CALC:MARK:MIN:LEFT
CALC:DELT:MIN:LEFT
EXCLUDE LO
The
EXCLUDE LO
softkey limits the frequency range for the marker search func-
tions or disables the limit.
Remote command:
CALC:MARK:LOEX ON
PEAK
EXCURSION
The
PEAK EXCURSION
softkey enables – for level measurements – the entry of a
minimum level value by which a signal must rise or fall so that it will be identified as
a maximum or a minimum by the
NEXT PEAK
and
NEXT MIN
search functions.
Valid entries are from 0 dB to 80 dB; the resolution is 0.1 dB.
Remote command:
CALC:MARK:PEXC 10dB
The default setting for the peak excursion is 6 dB. This value is sufficient for the
NEXT PEAK
and
NEXT MIN
functions since, in this mode, the next lower maximum
or next higher minimum will always be detected.
If
NEXT PEAK LEFT
or
NEXT PEAK RIGHT
is selected, these functions search for
the next relative maximum left or right of the current marker position irrespective of
the current signal amplitude.
Relative maximum
is understood to mean a decrease
of the signal amplitude by a defined value – i.e. the peak excursion – right and left of
the amplitude peak.
The 6 dB level change set as a default value may be attained already by the inher-
ent noise of the instrument. In such a case, the R&S FSP would identify noise peaks
as maxima or minima. The value entered for the
PEAK
EXCURSION
should there-
fore be higher than the difference between the highest and the lowest value mea-
sured for the displayed inherent noise.
The following example illustrates the effect of different settings of the
PEAK
EXCURSION
.
activated
Because of the feed through of the first local oscillator to the first
intermediate frequency at the input mixer, the LO is represented as a
signal at 0 Hz. To avoid the marker jumping to the LO at 0 Hz with the
peak function when setting the display range, this frequency is
excluded. The minimum frequency to which the marker jumps, is
≥
6
× resolution bandwidth (RBW).
deactivated
No restriction to the search range. The frequency 0 Hz is included in
the marker search functions.
Summary of Contents for R&S FSP Series
Page 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Page 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Page 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Page 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Page 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Page 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Page 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...