![Rohde & Schwarz R&S FSP Series Operating Manual Download Page 143](http://html.mh-extra.com/html/rohde-and-schwarz/rands-fsp-series/rands-fsp-series_operating-manual_1477864143.webp)
Operating Manual 1164.4556.12 - 06
4.71
R&S FSP
Instrument Functions
Analyzer Mode
SEARCH LIMIT
OFF
The
SEARCH LIMIT OFF
softkey disables all limits of the search range.
Remote command:
CALC:MARK:X:SLIM OFF
CALC:THR OFF
MKR->TRACE
The function of this softkey is identical to that of the
MKR
MKR->CF
STEPSIZE
The
MKR->CF STEPSIZE
softkey sets the step size for the center frequency varia-
tion to the current marker frequency, and also sets step size adaptation to
MANUAL
.
CF STEPSIZE
remains at this value until the center frequency entry mode in the
STEP
menu is switched from
MANUAL
to
AUTO
again.
The
MKR
->
CF STEPSIZE
function is, above all, useful in the measurement of har-
monics with large dynamic range (narrow bandwidth and narrow span).
The softkey is not available in the time domain (span = 0 Hz).
Remote command:
CALC:MARK:FUNC:CST
Example
The harmonics levels of a CW carrier are to be measured at 100 MHz.
MIN
The
MIN
softkey sets the active marker/delta marker to the minimum of the selected
trace.
Remote command:
CALC:MARK:MIN
CALC:DELT:MIN
NEXT MIN
The
NEXT MIN
softkey sets the active marker/delta marker to the next higher mini-
mum of the selected trace.
Remote command:
CALC:MARK:MIN:NEXT
CALC:DELT:MIN:NEXT
[
PRESET
]
R&S FSP is set to the default setting.
[
CENTER
: 100
MHz
]
R&S FSP sets the center frequency to 100 MHz. The span
is set to 200 MHz.
[
SPAN
: 1
MHz
]
The span is set to 100 MHz.
[
MKR->
]
MARKER 1 is switched on and set to the maximum value
of the signal.
[
NEXT
]
R&S FSP switches to the submenu.
[
MKR->CF STEPSIZE
]
The step size of the center frequency setting equals the
marker frequency (100 MHz).
[
CENTER
]
The center frequency entry mode is activated.
[
Right key
]
The center frequency is set to 200 MHz. The first harmonic
of the test signal is displayed.
[
MKR->:
PEAK
]
The marker is set to the harmonic and the level of the latter
is output in the marker info field.
Summary of Contents for R&S FSP Series
Page 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Page 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Page 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Page 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Page 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Page 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Page 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...