![Rohde & Schwarz R&S FSP Series Operating Manual Download Page 643](http://html.mh-extra.com/html/rohde-and-schwarz/rands-fsp-series/rands-fsp-series_operating-manual_1477864643.webp)
Operating Manual 1164.4556.12 - 06
6.249
R&S FSP
Remote Control – Description of Commands
TRIGger Subsystem
TRIGger<1|2>[:SEQuence]:LEVel:RFPower
-50 to –10 dBm
This command sets the level of the RF power trigger source.
Example:
"TRIG:LEV:RFP –20DBM"
Characteristics:
*RST value: -20 dBm
SCPI: device-specific
Mode:
A
This command is only available with option R&S FSP-B6 (TV and RF Trigger).
TRIGger<1|2>[:SEQuence]:LEVel:VIDeo
0 to 100PCT
This command sets the level of the video trigger source.
Example:
"TRIG:LEV:VID 50PCT"
Characteristics:
*RST value: 50 PCT
SCPI: device-specific
Mode:
A
TRIGger<1|2>[:SEQuence]:SLOPe
POSitive | NEGative
This command selects the slope of the trigger signal. The measurement starts on a positive or negative
slope of the trigger signal. The selected trigger slope applies to all trigger signal sources.
Example:
"TRIG:SLOP NEG"
Characteristics:
*RST value: POSitive
SCPI: conform
Characteristics:
SCPI: device-specific
Mode:
A
TRIGger<1|2>[:SEQuence]:SOURce
IMMediate | EXTernal | VIDeo | IFPower | RFPower | TV
This command selects the trigger source for the start of a sweep.
Parameter:
The trigger source selection has to be done with the command
TRIGger<1|2>[:
SEQuence]:SYNChronize:ADJust
.
The selection RFPower or TV is only available with option R&S FSP-B6 (TV and
RF Trigger).
The selection of trigger sources is extended by option FM Demodulator (R&S FS-
K7) (see manual for option).
IMMediate
Automatic triggering of the next measurement at the end of the
previous one. The value IMMediate)corresponds to the FREE RUN
setting.
EXTernal
The next measurement is triggered by the signal at the external
trigger input.
VIDeo
The next measurement is triggered by the detection of a signal at
the video filter output.
Summary of Contents for R&S FSP Series
Page 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Page 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Page 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Page 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Page 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Page 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Page 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...