![Rohde & Schwarz R&S FSP Series Operating Manual Download Page 445](http://html.mh-extra.com/html/rohde-and-schwarz/rands-fsp-series/rands-fsp-series_operating-manual_1477864445.webp)
Operating Manual 1164.4556.12 - 06
6.51
R&S FSP
Remote Control – Description of Commands
CALCulate Subsystem
Example:
"CALC:MARK3:TRAC 2"
'Assigns marker 3 in screen A to trace 2.
"CALC2:MARK:TRAC 3"
'Assigns marker 1 in screen B to trace 3.
Characteristics:
*RST value: -
SCPI: device-specific
Mode:
A
CALCulate<1|2>:MARKer<1...4>:X
0 to MAX (frequency | sweep time)
This command positions the selected marker to the indicated :
• frequency (span > 0)
• time (span = 0)
• level (APD/CCDF measurement)
If marker 2, 3 or 4 is selected and used as delta marker, it is switched to marker mode.
The measurement windows are selected via CALCulate1 (screen A) or 2 (screen B).
Example:
"CALC1:MARK2:X 10.7MHz"
'Positions marker 2 in screen A to frequency 10.7 MHz.
Characteristics:
*RST value: -
SCPI: device-specific
Mode:
A
CALCulate<1|2>:MARKer<1...4>:X:SLIMits:LEFT
0 to MAX (frequency | sweep time)
This command sets the left limit of the search range for markers and delta markers in the selected
measurement window. Depending on the x-axis domain, the indicated value defines:
• frequency (span > 0)
• time (span = 0)
The function is independent of the selection of a marker, i.e. the numeric suffix in MARKer<1...4> is
irrelevant.
If the time domain power measurement is active, this command limits the evaluation range to the trace.
Example:
"CALC:MARK:X:SLIM ON"
'Switches the search limit function on for screen A.
"CALC:MARK:X:SLIM:LEFT 10MHz"
'Sets the left limit of the search range in screen A to 10 MHz.
Characteristics:
*RST value: - (is set to the left diagram border on switching on search limits)
SCPI: device-specific
Mode:
A
The function is only available if the search limit for marker and delta marker is
switched on (
CALC:MARK:X:SLIM ON
).
Summary of Contents for R&S FSP Series
Page 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Page 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Page 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Page 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Page 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Page 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Page 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...