![Rohde & Schwarz R&S FSP Series Operating Manual Download Page 411](http://html.mh-extra.com/html/rohde-and-schwarz/rands-fsp-series/rands-fsp-series_operating-manual_1477864411.webp)
Operating Manual 1164.4556.12 - 06
6.17
R&S FSP
Remote Control – Description of Commands
CALCulate Subsystem
CALCulate<1|2>:DELTamarker<1...4>:LINK
ON | OFF
This command switches on and off a link of delta marker 1 to marker 1. If the link is switched on and
the x-axis value of the marker 1 is changed, the delta marker 1 will follow on the same x-position.
The suffix at DELTamarker can only be 1 or not present, because the functionality is only available for
marker 1 and delta marker 1.
Example:
"CALC1:DELT1:LINK ON"
Switches the link of marker1/delta marker 1 on.
Characteristics:
*RST value: OFF
SCPI: device-specific
Mode:
A
CALCulate<1|2>:DELTamarker<1...4>:MAXimum:LEFT
This command positions the specified delta marker to the next smaller maximum value to the left of
the current value (i.e. descending X values). The corresponding delta marker will be activated first, if
necessary.
Example:
"CALC:DELT:MAX:LEFT"
'Sets delta marker 1 in screen A to the next smaller maximum value to the left of
the current value.
Characteristics:
*RST value: -
SCPI: device-specific
Mode:
A
This command is an event and therefore has no *RST value and no query.
CALCulate<1|2>:DELTamarker<1...4>:MAXimum:NEXT
This command positions the specified delta marker to the next smaller maximum value of the trace.
The corresponding delta marker will be activated first, if necessary.
Example:
"CALC1:DELT2:MAX:NEXT"
'Sets delta marker 2 in screen A to the next smaller maximum value.
Characteristics:
*RST value: -
SCPI: device-specific
Mode:
A
This command is an event and therefore has no *RST value and no query.
CALCulate<1|2>:DELTamarker<1...4>:MAXimum[:PEAK]
This command positions the specified delta marker to the current maximum value of the trace. If
necessary, the corresponding delta marker will be activated first.
Example:
"CALC2:DELT3:MAX"
'Sets delta marker 3 in screen B to the maximum value of the associated trace.
Characteristics:
*RST value: -
SCPI: device-specific
Mode:
A
This command is an event and therefore has no *RST value and no query.
Summary of Contents for R&S FSP Series
Page 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Page 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Page 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Page 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Page 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Page 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Page 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...