![Rohde & Schwarz R&S FSP Series Operating Manual Download Page 573](http://html.mh-extra.com/html/rohde-and-schwarz/rands-fsp-series/rands-fsp-series_operating-manual_1477864573.webp)
Operating Manual 1164.4556.12 - 06
6.179
R&S FSP
Remote Control – Description of Commands
SENSe Subsystem
[SENSe<1|2>:]LIST:RANGe<1...20>:SWEep:TIME:AUTO
ON | OFF
This command controls the automatic coupling of the sweep duration on the frequency span and the
bandwidth settings in a spurious measurement range.
Example:
"LIST:RANG2:SWE:TIME:AUTO ON"
'Activates the coupling of frequency range and bandwidths in range 2
Characteristics:
*RST value: ON
SCPI: device-specific
Mode:
A
[SENSe<1|2>:]LIST:RANGe<1...20>:TRANsducer
<string>
This command sets the transducer factor for a range in the spurious measurement.
Example:
"LIST:RANG2:TRAN 'fac_1'"
'Sets the transducer factor fac_1 in range 2
Characteristics:
*RST value: --
SCPI: device-specific
Mode:
A